TURN OFF POWER TO FIXTURE BEING RETROFITTED.
REMOVE EXISTING LAMPS.
REMOVE EXISTING BALLAST / WIRE WAY COVER(S).
CUT POWER LEADS TO EXISTING BALLAST.
REMOVE EXISTING SOCKET PLATES.
REMOVE EXISTING BALLAST (DISPOSE IN ACCORDANCE WITH LOCAL
CODES).
"TEK" SCREW MOUNTING ANGLE TO TOP OF HOUSING, INDEXING OFF
7/8" KNOCK OUT.
PULL 2 - 3 INCHES OF BEAD-CHAIN THROUGH KEY- HOLE SLOT IN
MOUNTING ANGLE AND SECURE.
CONNECT BALLAST LEADS AND GROUND TO APPROPRIATE EXISTING
CONNECTIONS THEREIN
EXISTING HOUSING.
ONCE CONNECTION IS MADE PRESS R316 TIGHTLY AGAINST EXISTING
HOUSING AND SECURE BY
PULLING CHAIN THROUGH HOLE. ONCE HOUSING
IS SNUG, SECURE CHAIN BY SLIDING INTO SLOT.
WHEN HOUSING IS SECURE COIL EXCESS BEAD-CHAIN INTO CAP AND
PUSH ARROW CLIP
INTO HOLE IN HOUSING.
TO REMOVE CAP PULL LIGHTLY AND DISENGAGE ARROW CLIP.
INSTALL LAMPS AND TURN ON POWER.